| Bomgar B300™ Hard Disk Drive Field Replacement | Free Trial | Support Virtualization Blog | Webcasts |
|
||||
![]() |
Bomgar B300™ Hard Disk Drive Field ReplacementStatic-sensitive Devices Electrostatic discharge (ESD) can damage electronic components. To prevent damage to any printed circuit boards, it is important to handle them very carefully. The following measures are generally sufficient to protect your equipment from ESD damage. CAUTION
Hard Disk Drive Field Replacement The Bomgar B300™ uses a RAID 5 configuration across three hard drives. This allows you to remove a failed hard drive without any interruption and swap it with this field replacement. The appliance will detect when you remove the failed drive and will automatically configure and image the blank unit upon insertion. Single Hard Disk Failure Replacement Procedure CAUTION
After replacing the failed disk, the green and red LEDs on the new disk will blink and the audible alarm is silenced, indicating that the spare drive is rebuilding. This could take several hours, depending on the amount of data and the system load at the time. Once the rebuild is complete, the red LED will turn off. The front bezel can then be replaced. Important Before returning the defective RAID disk pack, locate the RMA Request form and follow the return instructions.